"Live" tab

From VIT company
Revision as of 12:22, 10 March 2015 by Sysop@vitcompany.com (talk | contribs) (1 revision)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

The «Live» tab

The main operator’s work implements in the «Live» tab. This tab displays the set of viewports which helps to control an object.

Viewport is a window of video flow output from a particular source in the application.

Customization of appearance of the “Live” tab is made by administrator in section “Viewports’ configuration” in the “Settings” tab. Description of setup process see in section “Customization of appearance of the “Live” tab”. Operator work with the “Live” tab is described in “Work with the “Live” tab”.

Customization of appearance of the «Live» tab

As it was mentioned above, customization of appearance of the “Live” tab is made by administrator in section “Viewports’ configuration” in the “Settings” tab. Depending on monitor resolution and the required monitoring conditions, a wide variety of viewports configurations can be selected.


This tab allows choosing configuration of viewports, the most convenient for the user and satisfies system requirements. The exterior view of the tab is shown at a figure “Live” tab. Tab “Viewport’s Configuration”.


“Live” tab. Tab “Viewport’s Configuration”


Its graphic display and text description are represented for each configuration (see fig. “Live” tab. Description of specific viewport’s configuration). Graphic display - this is how viewports will be displayed eventually on the “Live” tab, and a text description defines the configuration settings. The numbers in the description of viewport’s configuration are the number of viewports which will be displayed to the user. Letters – a type of display.



The description of types of configuration is shown in table1:

Table1. Types of viewport’s display
n, en proportions of the frame (3x4) are saved, all viewports are equivalent
w, ew proportions of the frame (3х4) are changed so that the viewports will be able to occupy the maximal area of the screen, all viewports are equivalent
vn the main (big) viewport is positioned vertically to the small ones
hn the main (big) viewport is positioned horizontally to the small ones


Also, the system allows minimization and maximization of viewports. For example, if operator chooses “1:4vn” resolution, he/she will be able to process 5 video flows simultaneously: one maximized and four minimized.


To setup viewport’s configuration select the required configuration from the list and click the button SaveButton.png “Save Settings” (see “Live” tab. Save viewports settings).


“Live” tab. Save viewports settings


Work with the «Live» tab

As it was mentioned above, the main operator’s work implements in the «Live» tab. This tab displays the set of viewports which helps to control an object.


The «Live» tab is shown on the figure “Live” tab. The general view.


“Live” tab. The general view


Viewport’s image can be minimized or maximized. Ordinary image in viewport is shown on the “Live” tab. Image in viewport.



To maximize the image, click ones on the left mouse button and scroll. The result is a change of shown image and emergence of large-scale editor. Dragging the square in the scale-editor changes the display area (see on fig. “Live” tab. Zoom in an image).



If there is more than one viewport and some was appointed as a main (one of viewports is much bigger than others), operator can determine which video flow will be displayed on the main viewport. Clicking minimized viewport, "maximizes" it to a big window, and the video flow that was outputted in a big window, will be displayed on the maximized viewport’s place.


For example, let we have settings, when main viewport broadcasts video from second channel (as you see on fig. “Live” tab. Selection of the “main” flow, 2 channel).


“Live” tab. Selection of the “main” flow, 2 channel


If you need to see third channel in the main viewort, click on it. This action changes system settings to ones, shown on fig. “Live” tab. Selection of the main flow, 3 channel: 3rd channel’s flow is shown in the main viewport and the 2nd channel’s flow is shown in viewport, where third flow was before changes.


“Live” tab. Selection of the main flow, 3 channel


In case when all viewports are equal (viewports windows are in equal size), clicking on the viewport does not change the position of the flow.


Note!


If one viewport is determined as main and others as additional, then “Identify” button displays on the main viewport only.


Detailed review of one of viewports:


“Live” tab. Viewport of the «Live» tab


Viewport contains next elements:

OverseerParkingEng53.png Alert is a message of the system about a recognized plate number. Depending on the operation mode of each channel, alerts may vary. In some modes it is assumed, that operator makes a decision on how to proceed the recognized vehicle. For detailed information see the "System messages" part of this manual.
OverseerParkingEng54.png Button for a manual definition of a number in the frame, see use of this button on fig. “Live” tab. Manual numbers entry
File:ViewportButton.png Button of the current viewport


If the system does not recognize the plate number of the vehicle, the operator can manually add it into the database. Clicking the "Define" button activates the bounding box, which has to be adjusted to the plate number size in the frame. Next you need to enter the vehicles plate number and select movement direction (entry or exit). This option is available only in the "Parking" mode. Occurrence of the relevant records in the tables of events and statistics is a result of this operation.


“Live” tab. Manual numbers entry



Attention!


Numbers must be entered in Cyrillic keyboard layout (RU or UA). Otherwise, the system displays a message about the mismatch of the number type and the real one.

System messages

During the operation, the system shows messages (alerts) to the operator. By pressing "Pass" button, the operator permits the vehicle to the parking (from the parking), and enters relevant entries in the event and statistics log. The lifetime of such alert is until the operator reacts on it: either lets vehicle pass to the parking (from the parking) or closes the alert by clicking the “х” key. In case of external crossing devices (barriers, gates) connection, their operation will be done by clicking the button "Pass".


Alerts color indicates the belonging of a recognized number to a particular group. Red alert color indicates the following events:

  • re-entry of a vehicle (the vehicle is already at the parking);
  • re-exit (a car is not parked at the moment).
OverseerParkingEng56.png Appears only on "entry attempt", i.e. before the vehicle enters the facility. Clicking "Pass" closes the alert, and the vehicle is being registered on the parking. If a vehicle leaves or the operator clicks “х”, the vehicle won't enter the parking. There is a possibility to choose appropriate group for the vehicle and its owner in the dropdown list.
OverseerParkingEng57.png Appears when the vehicle is entering the facility. Alert indicates belonging of the vehicle to the "Spring" vehicles group. Clicking "Pass" closes the alert, and the vehicle is being registered on the parking.
OverseerParkingEng58.png The alert appears when the vehicle is trying to re-enter the facility (for example, in case of incorrect exit from the facility).
OverseerParkingEng59.png Appears when the vehicle is exiting the facility. The stopping time is displayed; clicking the "Pass" button closes the parking for the particular vehicle.
OverseerParkingEng60.png Appears when the vehicle is exiting the facility. Alert indicates belonging of the vehicle to the "Other" vehicles group. Clicking the "Pass" button closes the parking for the particular vehicle.
OverseerParkingEng61.png Appears when the vehicle is exiting the facility incorrectly. Incorrect exit means, that the parking for the particular vehicle was not opened.
OverseerParkingEng62.png In case of an incomplete car license plate recognition (also if the operator clicked the line with the number (for editing) — in case of correct recognition) appears an alert containing "*", and the operator should edit the plate number himself. Alert with buttons «Entry» and «Exit» appears if system could not determine vehicles direction.
OverseerParkingEng63.png In case of an incomplete car license plate recognition (also if the operator clicked the line with the number (for editing) — in case of correct recognition) appears an alert containing "*", and the operator should edit the plate number himself. Alert contains “define” button in case system succeed in identifying movement direction of the vehicle.


Entry and exit of a vehicle from the facility

To pass a vehicle at the facility:

  • If plate number was recognized by the system automatically and there is no errors in the characters of number, than operator clicks “Pass” button on the entrance alert.
  • If plate number was partly recognized or has some errors:
  1. operator need to press on the plate number line in the entrance alert;
  2. edit plate number in the alert and press “Pass” (if movement direction was determined automatically) or “Enter” (if movement direction was determined manually);
  3. press “Pass” button on the entrance alert.


  • If plate number was not recognized, operator need to do next:
  1. press “Determine” button on the viewport;
  2. enter plate number in the edit alert and press “Pass” (if movement direction was determined automatically) or “Enter” (if movement direction was determined manually);
  3. press “Pass” button on the entrance alert.


Afterwards alert hides, recording data on the entry of the vehicle appears in the “Event” tab, and parking opens for the vehicle according to its group (parking data is available on the “Statistics” tab).


To let out a vehicle from the facility:

  • If plate number was recognized automatically and there is no errors in the characters of number, operator clicks “Pass” button on the exit alert.
  • If number plate was partly recognized or has some errors:
  1. operator need to press on the plate number line in the exit alert;
  2. edit plate number in the alert and press “Pass” (if movement direction was determined automatically) or “Exit” (if movement direction was determined manually);
  3. press “Pass” button on the exit alert.


  • If number plate was not recognized, operator need to do the next:
  1. press “Determine” button on the viewport;
  2. enter plate number in the edit alert and press “Pass” (if movement direction was determined automatically) or “Exit” (if movement direction was determined manually);
  3. press “Pass” button on the entrance alert.


Afterwards alert hides, recording data on the entry of a vehicle appears on the “Event” tab, and parking closes for the vehicle according to its group (parking data is available on the “Statistics” tab).