	<entry>
		<id>https://docs.vitcompany.com/index.php?title=MainConsole_configuration&amp;diff=645&amp;oldid=prev</id>
		<title>Sysop@vitcompany.com: 1 revision</title>
		<link rel="alternate" type="text/html" href="https://docs.vitcompany.com/index.php?title=MainConsole_configuration&amp;diff=645&amp;oldid=prev"/>
		<updated>2015-03-10T11:22:42Z</updated>

		<summary type="html">&lt;p&gt;1 revision&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;==Prior Configuration of MainConsole System==&lt;br /&gt;
&lt;br /&gt;
After installation of AutoCode NUUO it should be connected to MainConsole System to: &lt;br /&gt;
:* receive video and archive from MainConsole System;&lt;br /&gt;
:* send data on recognized plates to MainConsole System. &lt;br /&gt;
&lt;br /&gt;
==Live Streaming service configuration==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To configure Live Streaming service the following actions should be performed successively:&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# select option '''Network Service''' in the '''Setting menu''' (see pic. ''Network service'');&lt;br /&gt;
# in the window '''Network Service''' select '''Live Streaming''' tab and paste the  Live Streaming service parameters (see pic. ''Live Streaming service configuration''): &lt;br /&gt;
#* paste '''Port''', which will be used for video transfer AutoCode NUUO;&lt;br /&gt;
#* press the '''Start''' button to run Live Streaming service  and start video sharing;  &lt;br /&gt;
# press the '''ОК''' button to save configurations.&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU1.png|thumb|center|Network service| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU2.png|thumb|center|Live Streaming service configuration| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Remote Playback service configuration==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To configure '''Remote Playback''' service the following actions should be performed successively:&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# select option '''Network Service''' in the '''Setting menu''' (see pic. ''Network service'');&lt;br /&gt;
# in the window '''Network Service''' select ''Remote Playback''' tab and paste the  Live Streaming service parameters (see pic. ''Remote Playback service configuration''): &lt;br /&gt;
#* paste '''Port''', which will be used for video transfer AutoCode NUUO;&lt;br /&gt;
#* press the '''Start''' button to run Live Streaming service  and start video sharing;  &lt;br /&gt;
# press the '''ОК''' button to save configurations.&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU1.png|thumb|center|Network service| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU3.png|thumb|center|Remote Playback service configuration| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Configuration of metadata obtaining==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To configure obtaining data about recognized license plates (metadata) the following actions should be performed successively: &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
:* create new metadata source;&lt;br /&gt;
:* create new metadata channel; &lt;br /&gt;
:* customize filtration of received and displayed data;&lt;br /&gt;
:* specify data displaying parameters.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
===Creation of new metadata source ===&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To create new metadata source the following actions should be performed successively:&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# select option '''Metadata Application''' in the '''Setting menu''' (see pic. ''Metadata application'');&lt;br /&gt;
# press the button '''Insert'''  in the bottom of  '''Metadata Application''' window (see pic. ''Creation of new metadata source'');&lt;br /&gt;
# pecify connection to AutoCode NUUO parameters in the right part of window (see pic. ''New metadata source parameters''):&lt;br /&gt;
#* '''Name''' – name of new source, e.g. '''Metadata Source''';&lt;br /&gt;
#* '''Metadata Type''' – metadata type, select '''LPR''' option;&lt;br /&gt;
#* '''Source Type''' – source type, select '''VIT''' option;&lt;br /&gt;
#* '''VIT Server IP''' – AutoCode NUUO address, where recognition should be performed, should be specified;&lt;br /&gt;
#* '''VIT Server Port''' – port specified as Server port in AutoCode NUUO settings;&lt;br /&gt;
# click '''OK''' at the bottom of window to save configurations &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To check specified configurations correctness click '''Тest connection''' button. However, note that connection tests pass successfully only if metadata transferring has been already configured in AutoCode NUUO.  &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU4.png|thumb|center|Metadata application| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU5.png|thumb|center|Creation of new metadata source| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU6.png|thumb|center|New metadata source parameters| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
===Creation of new metadata channel===&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To create new metadata channel the following actions should be performed successively (see pic. ''Creation of new metadata channel''): &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# select created at the previous stage metadata source;&lt;br /&gt;
# press the button '''Insert'''  in the bottom of  '''Metadata Application''' window and specify metadata channel parameters:&lt;br /&gt;
#* '''Name''' – name of new source, e.g. '''Chan 1''';&lt;br /&gt;
#* '''Channel''' – number of channel which media data should be displayed. &lt;br /&gt;
# click '''OK''' button at the top part of window to save configurations. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU7.png|thumb|center|Creation of new metadata channel| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
===Specification of filtering parameters ===&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To specify filtering parameters the following actions should be performed successively (see pic. ''Specification of filtering parameters''):&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# select created at the previous stage metadata channel;&lt;br /&gt;
# specify event filtering parameterson the right part of the '''Metadata Application''' window : &lt;br /&gt;
#* '''Tag Filter''' - choose one of filters provided with AutoCode NUUO. If necessary filter is not available in the list, export it by clicking '''Import''' preliminarily;&lt;br /&gt;
#* '''Associated Cameras''' -  select camera on which data about recognized events should be displayed in Live View mode;&lt;br /&gt;
# click OK button at the top part of window to save configurations. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU8.png|thumb|center|Specification of filtering parameters| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
== Specify video parameters in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To receiving video and archive from MainConsole System the following actions should be performed successively (see pic. ''Receiving video and archive from MainConsole System''):&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# Open the Settings tab in AutoCode NUUO and go to the Channel settings options there. &lt;br /&gt;
# Select the channel that will receive video from MainConsole System in the right part of the window.&lt;br /&gt;
# Define the following channel parameters:&lt;br /&gt;
#*  '''Source type''' – Ip Camera;&lt;br /&gt;
#* '''Type''' – NUUO;&lt;br /&gt;
#* '''IP Address''' - the '''IP address''' of from MainConsole System: '''Login Management Server (Command Port)''';&lt;br /&gt;
#* '''Username''' and '''Password''' - the username and password of Crystal System;&lt;br /&gt;
#* '''Camera''' – click on “…” button to connect to MainConsole System and synchronize the camera list. After that select the '''Camera''' from the list appear;&lt;br /&gt;
#* '''Archive Access Port''' -  '''Recording Server LAN Settings (LAN Port)''';&lt;br /&gt;
# Select the viewport to display this channel stream.&lt;br /&gt;
# Save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainconsoleRU77.png|thumb|center|Receiving video and archive from MainConsole System| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Adjust LPR in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
To adjust LPR in AutoCode NUUO the following actions should be performed successively:&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# Open the '''Settings tab''' in AutoCode NUUO and go to the '''Channel settings''' options there. &lt;br /&gt;
# Select the channel that will receive video from Crystal System in the right part of the window.&lt;br /&gt;
# Select channel assignment as: &lt;br /&gt;
#* Parking for AutoCode NUUO Parking;&lt;br /&gt;
#* Demonstration or Flow for AutoCode NUUO Traffic.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU8.png|thumb|center|Selecting channel assignment| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# Go to the '''Recognition settings'''.&lt;br /&gt;
# Select '''Size of numbers''' option in the menu.&lt;br /&gt;
# Click on the '''Templates''' button.&lt;br /&gt;
# Select your country. &lt;br /&gt;
# Click '''Ok''' button to save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU9.png|thumb|center|LPR in AutoCode NUUO| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Specify metadata settings in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
For sending data on recognized plates to MainConsole System perform the follofing steps to define metadata channel's parameters: &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
# Open the Settings tab in '''AutoCode NUUO''' and go to the '''Channel settings''' options there.&lt;br /&gt;
# Select the channel that receives video from MainConsole System in the right part of the window.&lt;br /&gt;
# Define '''Server Port - TCP Server Port''' entered at setup 1.&lt;br /&gt;
# Save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndMainConsole88.png|thumb|center|Sending data on recognized plates to MainConsoleSystem| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[en:MainConsole configuration|MainConsole configuration]]&lt;br /&gt;
[[ru:Настройка системы MainConsole для работы с AutoCode|Настройка системы MainConsole для работы с AutoCode]]&lt;/div&gt;</summary>
		<author><name>Sysop@vitcompany.com</name></author>