	<entry>
		<id>https://docs.vitcompany.com/index.php?title=Crystal_configuration&amp;diff=643&amp;oldid=prev</id>
		<title>Sysop@vitcompany.com: 1 revision</title>
		<link rel="alternate" type="text/html" href="https://docs.vitcompany.com/index.php?title=Crystal_configuration&amp;diff=643&amp;oldid=prev"/>
		<updated>2015-03-10T11:22:42Z</updated>

		<summary type="html">&lt;p&gt;1 revision&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;== Setup 1. Create a new metadata source in Crystal System ==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Select '''NVR Metadata Server''' in the left part of '''Settings''' tab in '''NUUO Crystal NuClient''' application. &amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 2. Click «+» in the bottom of tab.&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU1.png|thumb|center|Creation of new metadata source| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 3. Specify connection to AutoCode NUUO parameters in the right part of window:&lt;br /&gt;
:* '''Name''' – name of new source, e.g. Metadata Source;&lt;br /&gt;
:* '''Description''' – short description of source, e.g. Autocode;&lt;br /&gt;
:* '''TCP Server IP''' – AutoCode NUUO address, where recognition will be performed;&lt;br /&gt;
:* TCP Server Port – port specified as Server port in AutoCode NUUO settings;&lt;br /&gt;
: Step 4. '''Click Сommit Config''' button at the top of window to save configurations. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU2.png|thumb|center|Data aboutnew metadata source| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 2. Create new metadata channel in Crystal System==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Select metadata source created at the previous setup.&lt;br /&gt;
: Step 2. Click «+» at the bottom of the tab. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU3.png|thumb|center|Creation of new metadata channel| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
Step 3. Specify metadata channel parameters in '''Properties''' tab:&lt;br /&gt;
:* '''Name''' – name of new channel, e.g. '''Metadata Channel''';&lt;br /&gt;
:* '''Description''' – short description of channel, e.g. Autocode;&lt;br /&gt;
Step 4. Click Сommit Config button at the top of window to save configurations. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU4.png|thumb|center|Creation of new metadata channel| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 3. Specify filtering parameters in Crystal System==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Select metadata channel created at setup 2. &lt;br /&gt;
: Step 2. On the upper panel select Filter tab.&lt;br /&gt;
: Step 3. Specify event filtering parameters: &lt;br /&gt;
:* '''Choose filter''' – choose one of filters provided with AutoCode NUUO. If necessary filter is not available in the list, export it by clicking Export preliminarily;&lt;br /&gt;
:* '''Filter name''' – paste filter name;&lt;br /&gt;
:* '''Encoding option''' – choose encoding of received data. Filters provided with AutoCode NUUO contain encoding in the name of the file;&lt;br /&gt;
: Step 4. Click '''Сommit Config''' button at the top part of window to save configurations.&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU5.png|thumb|center|Specification of filtering parameters| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 4. Specify metadata displaying parameters in Crystal System==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Select metadata channel created at setup 2. &lt;br /&gt;
: Step 2. Select '''Metadata Display''' on the upper panel. &lt;br /&gt;
: Step 3. Specify event displaying parameters:&lt;br /&gt;
:* font, its size and position of metadata in window with video;&lt;br /&gt;
:* '''Associated Camera''' – select camera where data about recognized events should be displayed in Live View mode;&lt;br /&gt;
: Step 4. click Сommit Config button at the top part of window to save configurations.&amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU6.png|thumb|center|Specification of metadata displaying parameters| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 5. Specify video parameters in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. open the Settings tab in AutoCode NUUO and go to the Channel settings options there. &lt;br /&gt;
: Step 2. Select the channel that will receive video from Crystal System in the right part of the window.&lt;br /&gt;
: Step 3. Define the following channel parameters:&lt;br /&gt;
:* '''Source type''' – Ip Camera;&lt;br /&gt;
:* '''Type''' – NUUO;&lt;br /&gt;
:* '''IP Address''' - the '''IP address''' of from Crystal System: '''Login Management Server (Command Port)''';&lt;br /&gt;
:* '''Username''' and '''Password''' - the username and password of Crystal System;&lt;br /&gt;
:* '''Camera''' – click on “…” button to connect to Crystal System and synchronize the camera list. After that select the '''Camera''' from the list appear;&lt;br /&gt;
:* '''Archive Access Port''' -  '''Recording Server LAN Settings (LAN Port)''';&lt;br /&gt;
: Step 4. Select the viewport to display this channel stream.&lt;br /&gt;
: Step 5. Save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU7.png|thumb|center|Receiving video and archive from Crystal System| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 6. Adjust LPR in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Open the '''Settings tab''' in AutoCode NUUO and go to the '''Channel settings''' options there. &lt;br /&gt;
: Step 2. Select the channel that will receive video from Crystal System in the right part of the window.&lt;br /&gt;
: Step 3. Select channel assignment as: &lt;br /&gt;
:* Parking for AutoCode NUUO Parking;&lt;br /&gt;
:* Demonstration or Flow for AutoCode NUUO Traffic.&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU8.png|thumb|center|Selecting channel assignment| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 4. Go to the '''Recognition settings'''.&lt;br /&gt;
: Step 5. Select '''Size of numbers''' option in the menu.&lt;br /&gt;
: Step 6. Click on the '''Templates''' button.&lt;br /&gt;
: Step 7. Select your country. &lt;br /&gt;
: Step 8. Click '''Ok''' button to save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalRU9.png|thumb|center|LPR in AutoCode NUUO| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
==Setup 7. Specify metadata settings in AutoCode NUUO==&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
: Step 1. Open the Settings tab in '''AutoCode NUUO''' and go to the '''Channel settings''' options there.&lt;br /&gt;
: Step 2. Select the channel that receives video from Crystal System in the right part of the window.&lt;br /&gt;
: Step 3. Define '''Server Port - TCP Server Port''' entered at setup 1.&lt;br /&gt;
: Step 4. Save the settings. &amp;lt;br/&amp;gt;&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[File:AutoCodeAndCrystalInt10.png|thumb|center|Sending data on recognized plates to Crystal System| 900px]]&lt;br /&gt;
&amp;lt;br/&amp;gt;&lt;br /&gt;
[[en:Crystal configuration|Crystal configuration]]&lt;br /&gt;
[[ru:Настройка системы_Crystal для работы с AutoCode|Настройка системы_Crystal для работы с AutoCode]]&lt;/div&gt;</summary>
		<author><name>Sysop@vitcompany.com</name></author>
	</entry>
</feed>